Server and console
JQ-872Workflow history too large
What it means
The run's history has more events or bytes than the server loads at once, and a replay or a version migration needs the whole history, so it is refused (422); the replay of an archived run is held to the same limits. Reading a history is not refused: it comes in pages.
How to fix it
A replay or a migration cannot be split: use continue-as-new so runs keep shorter histories. The run itself can still be read, cancelled or terminated.
- Raised by
- Server and console
- Since
- 0.7.2
- Was
- history_too_large
Still stuck? The troubleshooting guide maps symptoms to causes.